Key takeaways

  • The exact contactor or starter model and frame size already in the panel.
  • Whether the block mounts on the front, side, or top of the contactor (manufacturers differ on this).
  • The contact rating needed for the control circuit voltage (common control circuits run at 24V DC, 120V AC, or 240V AC).
  • How many additional poles the application needs – many blocks come in 1NO+1NC, 2NO, 2NC, or 4-pole combinations.

Electricians and panel builders replacing or adding signaling contacts on a motor starter should match the auxiliary contact block to the starter’s brand and frame size first, then choose the contact configuration (normally open, normally closed, or a combination block) based on what the circuit needs to monitor or interlock.

An auxiliary contact is a low-current signaling contact mounted on or added to a motor starter or contactor. It does not carry the motor’s load current; instead it tells a PLC, indicator light, timer, or another starter that the main contactor has changed state. Because these add-on blocks are mechanical accessories rather than standalone products, the single most important spec is mechanical and electrical compatibility with the exact starter or contactor line already installed in the panel.

Why Fit Matters More Than Brand Here

Auxiliary contact blocks are not universal. Each major contactor manufacturer uses its own mounting profile, so a block made for one brand’s frame will not snap onto a different brand’s contactor without an adapter, and in many cases no adapter exists at all. Before ordering, confirm:

  • The exact contactor or starter model and frame size already in the panel.
  • Whether the block mounts on the front, side, or top of the contactor (manufacturers differ on this).
  • The contact rating needed for the control circuit voltage (common control circuits run at 24V DC, 120V AC, or 240V AC).
  • How many additional poles the application needs – many blocks come in 1NO+1NC, 2NO, 2NC, or 4-pole combinations.

Contact Configurations Explained

Normally open (NO)

Stays open until the contactor energizes, then closes. Commonly used to light a “running” indicator or send a run-confirmation signal to a controller.

Normally closed (NC)

Stays closed until the contactor energizes, then opens. Often used for “stopped” indication, interlocking (preventing a second starter from energizing while the first is running), or alarm circuits.

Combination blocks (1NO+1NC or 2NO+2NC)

Give one add-on block both signal types at once, which is typical when a panel needs both a run light and a stop/alarm signal from the same starter without using two separate blocks.

At a Glance: Auxiliary Contact Block Types

Block type Best for Key stated specs Limits
Side-mount, single pole (1NO or 1NC) Simple run/stop indication on small starters Snaps to the side of the contactor; rated for standard control-circuit voltages Only adds one signal; frame-specific fit
Combination block (1NO+1NC) Panels needing both a run light and an alarm/interlock signal Two independent contacts in one mounting block Takes more panel space; still brand/frame specific
Front-mount, multi-pole (2NO+2NC or more) PLC integration needing several simultaneous status points Higher pole count for monitoring multiple circuit states at once Larger footprint; higher cost than single-pole blocks
Early-break / late-make auxiliary contacts Interlocking circuits where timing between contacts matters Switches slightly before or after the main contacts for safety sequencing Specialized use case; not needed for basic indication

Pick-X-If Decision Table

Pick this if… Choose
You just need a “motor running” pilot light Single-pole NO side-mount block matched to your contactor brand
You need both run indication and a fault/alarm signal A combination 1NO+1NC block
Your PLC needs several independent status inputs from one starter A multi-pole front-mount block
You are building a safety interlock between two starters An early-break or late-make auxiliary contact rated for that function, installed per the electrical code and the starter maker’s instructions
You are not sure which block fits your contactor Contact the contactor manufacturer or a qualified electrical distributor with the starter’s model number before ordering

Compatibility and Safety Notes

Because auxiliary contacts attach to and interact with motor control circuits, installation should be done by a qualified electrician familiar with the panel’s wiring diagram and local electrical code. Always de-energize and lock out the panel before adding or replacing an auxiliary contact block, and verify the contact’s current and voltage rating against the control circuit it will serve – these blocks are rated for pilot-duty signaling loads, not for switching motor current directly. If a block is being added to a starter that is part of a safety circuit, such as an emergency-stop interlock, follow the starter manufacturer’s documented wiring diagrams exactly, since miswiring an auxiliary contact in a safety circuit can defeat the interlock.

Alternatives Worth Considering

Integrated starters with built-in auxiliary contacts

Some newer motor starters and contactors ship with one or two auxiliary contacts already built in, which avoids the fit question entirely if the application’s signaling needs are modest.

Smart/communicating overload relays

For panels already using a networked PLC, a communicating overload relay can report running, tripped, and fault states over the network instead of (or alongside) hard-wired auxiliary contacts, reducing the number of physical contact blocks needed.

Separate control relays

When a starter’s own contactor has no room for an add-on block, a small interposing control relay driven by the starter’s existing auxiliary contact can multiply the number of available signal contacts.

Frequently Asked Questions

Can I use any brand’s auxiliary contact block on my contactor?

Generally no. Mounting profiles are brand- and often frame-size-specific, so the block has to match the exact contactor line installed. Checking the starter’s model number against the contactor maker’s accessory catalog before ordering avoids a mismatched part.

What is the difference between an auxiliary contact and the main contacts on a starter?

The main contacts switch the motor’s load current and are sized for that duty. Auxiliary contacts are low-current signaling contacts rated only for pilot-duty loads like indicator lights, relay coils, or PLC inputs, and should never be wired to carry motor current.

How many auxiliary contacts can be added to one starter?

This depends on the contactor’s frame size and how many mounting positions the manufacturer provides; small frames often support one or two add-on blocks, while larger frames may support more. The contactor’s own documentation lists the maximum.

Do auxiliary contacts need their own fuse or circuit protection?

Control circuits that auxiliary contacts feed into are typically protected by the panel’s control circuit fuse or breaker rather than a dedicated fuse on the contact itself; a qualified electrician should verify this against the panel’s design and local code.

What does “early break” or “late make” mean for an auxiliary contact?

These describe contacts engineered to switch slightly before (early break) or after (late make) the main contactor contacts, which is used in interlocking circuits where the timing sequence between two starters matters for safety.

Can an auxiliary contact block be retrofitted onto an older starter still in service?

Often yes, if the exact model and frame size can be identified and the manufacturer still lists a matching accessory. If the starter is obsolete or the model cannot be confirmed, consulting an electrical distributor or the panel’s original integrator is the safer path before ordering a part that may not fit.